UNDERGROUND FLOOR CONSTRUCTION
Construction of walls and floor of an in-ground technical room by wet shotcreting without panel forms. В20 W8 F300 fine grain concrete was used. This structure is waterproof as there are no cold seams. No subsequent waterproofing is necessary. Work was accomplished over 5 hours. 9m3 of concrete were placed in total.